EK-D09
Dense inorganic ceramic composite coating
High-temperature anti-corrosion ceramic coating matching EK-D08's performance; the grades differ mainly in colour.
FORM
One-component coating
APPEARANCE
Gray-blue
CURING
260 (air) · 60 h
Documents
TDS · SDS
The material
How this grade works and where it fits — exact parameters are defined in the TDS.
This product uses polysilazane as the film-forming material, compounded with high-temperature-resistant ceramic fillers, ultrafine powders, plastic fillers and other components. After high-temperature curing it converts into an inorganic ceramic composite coating. The high-temperature conversion forms a Si-C-N ceramic structure, producing a dense, ultra-high-temperature-resistant coating on metal substrates that can serve long-term in 1000 °C environments without cracking, flaking or discoloration. The coating is abrasion-resistant, dense and corrosion-protective.
Application areas: (1) boiler components, petrochemical blast furnaces, inner and outer walls of hot-blast stoves, chimneys, flues, exhaust pipes; (2) high-temperature devices, high-temperature sensor components; (3) surfaces of metallurgical equipment, molds and casting equipment; (4) electric heating elements, tanks, cabinets, heat exchangers, radiators; (5) small household appliances and kitchenware (burner caps, rice cookers), etc.; (6) high-temperature components in the chemical and metallurgical industries.
This grade matches EK-D08's profile (800 °C service, ≥8H, ≥1000 h salt spray) — the two differ mainly in colour. Choose by the required finish; the team will confirm available colours.
Final fit is confirmed during technical review — send your substrate, operating environment and application process, and the team will confirm this grade or point you to a closer one.
Suitable for
Industrial applications within the TDS parameters
Metal, glass, ceramic and stone substrates — per grade
Professional application and curing processes
Not intended for
Consumer or DIY use — industrial B2B supply only
Conditions outside the parameters defined in the TDS
Food-contact or medical use unless explicitly confirmed
Applications
Recommended application areas for this grade, based on its TDS. Application fit is confirmed during technical review.
Recommended applications for this grade:
Technical data
Key values from this grade's TDS. The complete measured data set follows below; the official document is available on request.
PROPERTY
TYPICAL VALUE
NOTES
Solid content
>85 %
—
Viscosity
25–38 s
—
Max service temperature
-30 to 800 °C service
Depends on cure & film build
Curing conditions
260 (air) · 60 h
Per application process
Recommended film thickness
10–40 µm
—
Shelf life
6 months (storage at 10–30 °C)
Storage conditions apply
Service temperature. Maximum withstand temperature with nitrogen curing 1300 °C (limited by the metal substrate); suitable for long-term service at 1000 °C (limited by the metal substrate); withstands long-term direct impingement by flame or high-temperature gas flow. The temperature resistance of the coating varies with the temperature capability of the substrate (note: product performance differs depending on the substrate).
Basic Coating Data
Coating appearance: Gray-blue — Visual inspection
Coating components: Two-component
Mixed density: 1.78–1.95 g/cm³ — Measured
Coating Film Properties
Condition in container: Uniform, free of lumps and sediment — Visual inspection
Mixed color: White / gray — Visual inspection
Mixed viscosity: 25–38 s — GB/T 1723-1993
Adhesion: Grade 0 (cross-cut) — GB/T 9286-1998
Coating film hardness: ≥8H — GB/T 6739-2006
Aging resistance: 30 d: no rusting, no chalking, no cracking, no discoloration — GB/T 1865-2009
Neutral salt spray resistance: ≥1000 h: no blistering, no rust spots, no flaking — GB/T 10125-2021
High-temperature test: 1000 °C / 24 h: no flaking, no cracking — GB/T 30873-2014
Basic Application Parameters
Coating solids content (%): >85
Theoretical coverage (m²/kg): 8–15
Dry film thickness (µm): 10–40
Working time (pot life) (h): 12
Thinner: Alkanes, esters, ethers, etc.
Flash point (°C): <22 (solvent flash point)
Volatility: Low volatility
Curing temperature (°C): 260 (air)
Curing time (min): 60
Maximum temperature resistance (°C): 1300
Recommended service temperature (°C): -30 to 800
Warehouse storage (°C): 10–30
Data above is taken from the manufacturer’s TDS. Request the official document via the documents section below.
Substrates & storage
Compatibility and handling essentials — confirmed per grade in the TDS and SDS.
Suitable substrates
Steel and stainless steel
Aluminium and other metals
Glass and ceramics
Stone and mineral surfaces
310S stainless steel, 316 stainless steel and other high-temperature alloy steels. Note: the coating formulation differs for different substrates; within a certain range it can be adjusted and matched to the substrate and its service conditions.
Storage, packaging & transport
Store in accordance with national regulations, in a dry, cool and well-ventilated environment away from heat sources and open flames. Packaging containers must be kept tightly closed and placed with care.
Maintain the storage temperature between 10 °C and 30 °C; the shelf life is 6 months.
Coating that has been opened but not used up must be resealed under the container lid and stored sealed.
Mixed coating that is not used up cannot be reclaimed; dispose of it in accordance with local regulations.
Product past its shelf life may be used only after testing confirms it is still acceptable.
Packaging
1 kg / 5 kg / 25 kg (grade-dependent)
Transport classification
Per SDS
Application process
General guidance — exact parameters are provided in the TDS and Application Guide.
01
Surface preparation
Clean, degrease and prepare the substrate.
02
Application
Spray, dip or wipe depending on grade.
03
Curing
Cure per the TDS conditions.
04
Quality control
Verify film build and adhesion.
Standard process: Surface cleaning → Abrasive roughening → Cleaning and blow-off → Spray/blade coating → Curing
Abrasive roughening. Before coating, sand or grit-blast the substrate surface to remove rust, dust, dirt and other matter adhering to the workpiece surface. Roughening strongly affects coating performance — Sa2.5 is optimal and St3 with no mill scale is the minimum (GB/T 30790.4-2014) — so give this step full attention.
Cleaning. Use a dedicated cleaning agent or degreaser to remove oil, dust and other residues remaining on the roughened surface.
Substrate drying. Before coating, ensure the substrate surface is dry and clean.
Coating mixing. This is a two-component product: take an appropriate amount of coating at the specified mixing ratio, stir until thoroughly and uniformly mixed, and filter through a 180-mesh screen before use.
Coating application. For laboratory spray application, a spray gun with a 1.0 nozzle orifice gives better appearance and uniformity.
Curing. Air curing provides temperature resistance up to 700 °C; nitrogen curing provides maximum temperature resistance of 1300 °C (contact the supplier for nitrogen-curing conditions).
Note: This product is a two-component heat-curing product; use the mixed coating within 12 hours. Over longer application periods, clean application tools promptly to prevent them from setting solid. Dry film thickness should not exceed 35 µm, otherwise coating film performance will decline.
More grades
Browse the full catalogue by category, or send your requirements — we will recommend a grade for your case.
Organic Polysilazane Resins
→
Inorganic Polysilazane / Ceramic Precursors
→
Modified Polysilazane Coatings
→
Ready-to-use Ceramic Coatings
→
High-temperature Ceramic Coatings
→
Electrical Insulation Coatings
→
Fluorosilanes & Surface Modifiers
→
Adhesives
→
Additives
→
Polycarbosilane
→
SiC Fibers
→
Ordering & logistics
Common questions from procurement and engineering teams.
What packaging formats are available?
Standard packaging is 1 kg, 5 kg and 25 kg containers, grade-dependent. Other formats, minimum order quantity, lead times, shipping terms and stock availability are confirmed on request.
What is the minimum order quantity for this product?
MOQ depends on the packaging format — confirmed by our team for your grade and volume.
What happens after I send an inquiry?
Our technical team reviews your requirement and responds with a recommendation, the relevant documents and next steps.
How do I get a quotation?
Include your estimated volume and application in the inquiry — a quotation follows the technical review.
How is the product shipped?
Packaging, transport classification and shipping details are provided per SDS — request packaging and shipping information with your inquiry.